Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 28(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36677820

RESUMO

This work reports the performance of a green corrosion inhibitor with double hydrocarbon chain. The evaluated inhibitor was a dialkyl-diamide from coffee bagasse oil and its electrochemical behavior was evaluated on an API-X52 steel in CO2-saturated brine at 60 °C. The electrochemical behavior was determined by measurements of open circuit potential, polarization resistance, and electrochemical impedance spectroscopy. In addition, the thermodynamic parameters of the corrosion process were obtained in the temperature range from 40 °C to 80 °C. Electrochemical studies showed that the inhibitor is capable of suppressing metal dissolution by up to 99% at 25 ppm. On the other hand, the thermodynamic parameters indicate that when adding the inhibitor, there is a strong increase in both Ea and ΔH° values, and that as time increases, they decrease until reaching similar values to those observed in the absence of the inhibitor. Furthermore, ΔS° values tend to become more negative with immersion time because of the formation of a stable film on the metal surface.


Assuntos
Dióxido de Carbono , Café , Corrosão , Diamida
2.
Materials (Basel) ; 14(15)2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34361400

RESUMO

A gemini surfactant imidazoline type, namely N-(3-(2-fatty-4,5-dihydro-1H-imidazol-1-yl) propyl) fatty amide, has been obtained from the fatty acids contained in the mango seed and used as a CO2 corrosion inhibitor for API X-120 pipeline steel. Employed techniques involved potentiodynamic polarization curves, linear polarization resistance, and electrochemical impedance spectroscopy. These tests were supported by detailed scanning electronic microscopy (SEM) and Raman spectroscopy studies. It was found that obtained gemini surfactant greatly decreases the steel corrosion rate by retarding both anodic and cathodic electrochemical reactions, with an efficiency that increases with an increase in its concentration. Gemini surfactant inhibits the corrosion of steel by the adsorption mechanism, and it is adsorbed on to the steel surface according to a Langmuir model in a chemical type of adsorption. SEM and Raman results shown the presence of the inhibitor on the steel surface.

3.
Materials (Basel) ; 13(21)2020 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-33137870

RESUMO

In this work, the effect of the addition of noble metals on the order-order disorder process of the L12 structure corresponding to the intermetallic Ni3Al is analyzed. Stoichiometric, nonstoichiometric, and quasi-binary compositions doped with noble metals such as Ag, Au, Pd, and Pt (1 at%) were analyzed. It was observed that depending on the composition, there is a modification in the activation energies calculated from the two time constants that characterize the disorder process. The statistic of atomic jumps was typified based on the configuration of the window to be crossed and, with this, it was identified that the origin of the negative activation energy of the long disorder process is due to an increase in the corresponding energy of the AlAl-Ni jump through unnatural windows.

4.
Materials (Basel) ; 12(22)2019 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-31752305

RESUMO

In this study, the performance evaluation of lanthanum compounds as corrosion inhibitors of vanadium salts was performed. The inhibitors tested were lanthanum acetate and La2O3. The performance of the inhibitors was tested using sodium metavanadate (NaVO3) as a corrosive medium at 700, 800, and 900 °C. The corrosion inhibitory effect was evaluated on the corrosion process of 304H stainless steel. The corrosion rate of the steel was determined by the mass loss technique after 100 h of immersion in the corrosive salt with and without the addition of the corrosion inhibitor. The results show that lanthanum compounds act as corrosion inhibitors of vanadium salts. The inhibitory effect increases by increasing the concentration and tends to decrease when increasing the test temperature. Lanthanum compounds act as excellent corrosion inhibitors due to their ability to stabilize vanadium cations. Vanadium is stabilized by forming a new compound, lanthanum vanadate (LaVO4), with a melting point much higher than the compounds formed when Mg or Ni compounds are used as corrosion inhibitors.

5.
Bioinorg Chem Appl ; 2016: 4792583, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27660601

RESUMO

In this work we proposed to evaluate the corrosion resistance of four different alloys by electrochemical techniques, a binary alloy Cu10Al, and three ternary alloys Cu10Al-xAg (x = 5, 10, and 15 wt.%) to be used like biomaterials in dental application. Biomaterials proposed were tested in artificial saliva at 37°C for 48 h. In addition, pure metals Cu, Al, Ag, and Ti as reference materials were evaluated. In general the short time tests indicated that the Ag addition increases the corrosion resistance and reduces the extent of localized attack of the binary alloy. Moreover, tests for 48 hours showed that the Ag addition increases the stability of the passive layer, thereby reducing the corrosion rate of the binary alloy. SEM analysis showed that Cu10Al alloy was preferably corroded by grain boundaries, and the Ag addition modified the form of attack of the binary alloy. Cu-rich phases reacted with SCN(-) anions forming a film of CuSCN, and the Ag-rich phase is prone to react with SCN(-) anions forming AgSCN. Thus, binary and ternary alloys are susceptible to tarnish in the presence of thiocyanate ions.

6.
Bioinorg Chem Appl ; 2015: 930802, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064083

RESUMO

Several austenitic stainless steels suitable for high temperature applications because of their high corrosion resistance and excellent mechanical properties were investigated as biomaterials for dental use. The steels were evaluated by electrochemical techniques such as potentiodynamic polarization curves, cyclic polarization curves, measurements of open circuit potential, and linear polarization resistance. The performance of steels was evaluated in two types of environments: artificial saliva and mouthwash solution at 37°C for 48 hours. In order to compare the behavior of steels, titanium a material commonly used in dental applications was also tested in the same conditions. Results show that tested steels have characteristics that may make them attractive as biomaterials for dental applications. Contents of Cr, Ni, and other minor alloying elements (Mo, Ti, and Nb) determine the performance of stainless steels. In artificial saliva steels show a corrosion rate of the same order of magnitude as titanium and in mouthwash have greater corrosion resistance than titanium.

7.
J Anal Methods Chem ; 2014: 503618, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25210645

RESUMO

Corrosion behavior of Ni20Cr coatings deposited by HVOF (high velocity oxygen-fuel) process was evaluated in ZnCl2-KCl (1 : 1 mole ratio) molten salts. Electrochemical techniques employed were potentiodynamic polarization curves, open circuit potential, and linear polarization resistance (LPR) measurements. Experimental conditions included static air and temperatures of 350, 400, and 450°C. 304-type SS was evaluated in the same conditions as the Ni20Cr coatings and it was used as a reference material to assess the coatings corrosion resistance. Coatings were evaluated as-deposited and with a grinded surface finished condition. Results showed that Ni20Cr coatings have a better corrosion performance than 304-type SS. Analysis showed that Ni content of the coatings improved its corrosion resistance, and the low corrosion resistance of 304 stainless steel was attributed to the low stability of Fe and Cr and their oxides in the corrosive media used.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...